| To: | "Lahtinen, Marko" <MARKOL@isr.gov.au> |
|---|---|
| Subject: | Re: electrics |
| From: | "David R. Conrad" <conrad1@gte.net> |
| Date: | Thu, 06 May 1999 09:08:15 -1000 |
Marko: Almost too simple, but I have had those symptoms more than once, from a bad connection at the battery positive terminal. Even had a service call, jump start, on one occasion. With the hood open, the last time it happened I could see a wisp of smoke rising from that terminal after the solenoid clicked in. Then I fixed it good! Hope the solution to your problem is that simple... Dave '68 1600 Kailua-Kona |
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Head Specs, JLBrooksNC |
|---|---|
| Next by Date: | Re: electrics, pkort |
| Previous by Thread: | Re: electrics, CarterCM |
| Next by Thread: | Re: electrics, pkort |
| Indexes: | [Date] [Thread] [Top] [All Lists] |