I have seen brake switches pass the multimeter continuity test
because the meter was not set at x1. At higher ranges (x1000) u
might get fooled by a full scale needle deflection that looks
like zero ohms but is not. That small bit of resistance can
prevent stop lite current flow.
BTW for a short circuit you want zero ohms not infinity.
Mike L
60A,67E,59Bug
----- Original Message -----
From: <Duinhoven_Hans@emc.com>
To: <smitty29832@msn.com>
Cc: <mgs@autox.team.net>
Sent: January 15, 2002 8:11 AM
Subject: RE: MGB Brake Light Trouble
> Take the switch out of the pedal cover.
> Connect both leads to the switch contact pins. The meter should
indicate a
> short circuit.
> When pressing the switch acturator (small pin near the screw
thread of the
> switch) the meter should read infinite ohms
///
/// mgs@autox.team.net mailing list