> the anti run on valve shuts off gas to the carb when the ignition is shut
> off. It is located on the top of the firewall on the passenger side. Look
> for a small part with hoses coming out of it. 
> ...Art
> 
My '72 doesn't have one, so take this with a grain of salt, but I 
thought that the anti run-on valve just created a huge vacuum leak 
when the ignition was turned off, effectively killing the engine.  
This would make more sense than a fuel cut-off, since the fuel in the 
carb bowl would allow the engine to run on for a while even with the 
fuel suppply cut off to the carb.
Scott