In a message dated 6/14/2006 8:19:49 PM Central Standard Time, 
tr3driver@comcast.net writes: 
> >However, there is a sneak circuit in that the pump and
> >valve will be
> >wired in series once the switch switches.  The pump and valve
> >will pass current
> >to the rest of the switched loads.
> 
> Good point (which I missed before), although since it's only a relay coil
> for the pump, there won't be much current passed.
> 
> However, a simple diode in series with the pump relay will solve the
> problem.
> 
Relay?  Did I miss something?  Most people don't bother with relays for the 
small pumps since they only draw a few amps.  But if you are using a relay then 
indeed a diode will solve that sneak circuit.  But then you should put in an 
MOV across the relay coil (or the diode) to prevent the inductive kick back 
from over stressing the diode.