I would check the generator with a voltmeter so see which way it is
charging. Or barring that, for even less work, I'd just polarize the
generator as if I was converting it from one ground to the other. About
the only concern then might be the fuel pump. Some electrical fuel pumps
are designed for one ground, MGBs anyway. Otherwise, everything else
should work fine.
David Councill
72 MGB
67 MGBGT
73 MGB
-----Original Message-----
> "Use a voltmeter leaps to mind.
> Put he positive lead on the voltmeter on the grounded terminal of the
> battery. Put the negative lead on the other terminal.
> If the voltmeter reads 12V it is positive ground
> If the voltmeter reads -12V it is negative ground"