Thread-index: Nc/IqcsKmE+GrUubYsLboRk3rJTrOw== s=q20140121; t=1446763080; bh=7eUuspSqh5N/tG/jYVjmjOx1kVrHMxPq1WSIdiUwrg0=; h=Received:Received:Date:From:To:Message-ID:Subject:MIME-Version: Content-Type; b=bhcp1T9yzz1+gW3FmIPcIDQEOO2G52L7C4kLlitWnNes05AOcsQAKyjE5mNDcQLMh h/xQ0lLlrwDHj5T4boJRQ4Z1sBlwn6Hm8NiAJwDOB8MBjve8U2tVuCHXTWdfPQ0R8H paeSQNew1sGUveXO09y/pKXed8QbwZjHU/+AJkyO4ARfgkBwCGEA+Mv63dxyX+01k0 UlwaEGVfObEkgWBXAnfwd+NpV+9fqjgSbNchQqaoS/+JEjpeee644bs8qVZn3jsCjr PaNf8fnDdgoODavuU3pvoF8Ib+w2UrdlQYx1BXU7kbyagm2WEiQzcZEuSM89GQ1Sp0 5wYvLpcFbh3vA==
Thread-topic: TR3 Voltage Regulator
Hi, everyone.  Installed the LED headlights, so am taking opportunity to 
deinstall the alternator conversion.

Put the rebuilt generator in, hooked up the wires to the voltage regulator 
correctly and drove to work the next day.  Charging according to my voltmeter 
(replaced the old ammeter with one) at 15 amps.  Right at spec.

Next morning at start up, the ignition light went on and wouldn't go off.  
Voltmeter read 12 volts because of the battery power going in, but no charge 
from the generator.  

After checking all wires and grounds, tonight I took the cap off the voltage 
regulator, shorted the break switch, and the ignition light went on with the 
key off...what you would expect.  Started the car and the voltmeter showed 12 
volts that jumped to 13 at rev.  I adjusted the regulator switch clockwise and 
bumped the charge to 15 at rev.  Seems that the generator is producing power.  
Test shows that at startup without shorting the cutout switch, the cutout 
switch fails to engage.  Now I know where the problem is.

Easiest at this point to just replace the regulator.  Cheap enough.  But 
question.

Moss indicates regulators don't come nicely adjusted, unless you spend extra to 
buy that feature.  Is this really necessary?

Terry Smith, '59 TR3A
New Hampshire