To: Michael Galloway <mgx@icesar.epm.ornl.gov>
Subject: re: spit fuses
From: Steve Sutton <ssutton@ridgecrest.ca.us>
Date: Tue, 8 Apr 1997 23:27:52 -0700
Cc: triumph mail exploder <triumphs@Autox.Team.Net>
Conversation-id: <Pine.SUN.3.91.970408125225.8198Q-100000@icesar.epm.ornl.gov>
Posted-date: Tue, 8 Apr 1997 23:30:09 -0700 (PDT)
Yes,  this is correct.  In fact I recently bought some new fuses for my TR-6
from TRF.  Genuine Lucas and imprinted was "35A  /  17A continuous".  If you
don't have the correct fuses handy, use ONLY a 15 amp slow-blow.  

I would not be suprised to find that alot of melted wiring harnesses were
caused by the owners mistakenly putting in 'regular' 35Amp slow-blow fuses
'cause the old fuses said 35Amp.......
>  From: Michael Galloway <mgx@icesar.epm.ornl.gov>, on 4/8/97 10:56 PM:
>  is this really correct? i replace my spit fuses with 30A slowblo's
>  per the Hayne's manual spec of 35A. 
>  
>  -- m
>  
>  On Mon, 7 Apr 1997, Steve Sutton wrote:
>  
>  > The fuses are in reality 17 amp continuous/ 35 amp surge.  You might get
by
>  > with normal 15 amp slow-blow fuses if you don't have a handy source for
the
>  > correct fuses.  Don't put in 35 amp slow-blow fuses though as the wiring
>  > harness melts at around 25 amps continuous! 
>  >  
>  
>  
>  