To: ShopTalk <shop-talk@autox.team.net> definitions=2020-08-13_14:2020-08-13, 2020-08-13 signatures=0 malwarescore=0 phishscore=0 bulkscore=0 spamscore=0 clxscore=1015 mlxscore=0 mlxlogscore=999 adultscore=0 classifier=spam adjust=0 reason=mlx scancount=1 engine=8.0.1-2004280000 definitions=main-2008130113
Subject: Re: [Shop-talk] Looking to buy a compressor
From: Darrell Walker <darrellw360@mac.com>
Date: Thu, 13 Aug 2020 07:58:59 -0700
Delivered-to: mharc@autox.team.net
Delivered-to: shop-talk@autox.team.net
References: <CAAoSWGP4h6i6Djkd6SAkjqYE_4XBsHWDOy+KRam_KUtiWtV4rg@mail.gmail.com> <D397E0C6-D2DD-491C-841F-45303D84DB5E@icloud.com> <CCEB47CD-90E8-4A64-9223-AB57C25C0DBF@me.com>
OK, I will submit to the wisdom of the list and mount the radiator between the 
pump and tank  :)

I will wait until I know the compressor is running fine, though it will be a 
mostly bolt-on installation and can be undone.

Since I already have the transmission cooler, Iâ??m going to use that, and 
mount it on the fan guard cage, so that some of the air from the fan will be 
pulled through the radiator. I know this will increase the temperature of the 
air that then goes to cool the pump, so Iâ??ll keep an eye on that.

The question I have is what to use for plumbing.  Since there could be some 
movement between the compressor cage and the rest of the compressor, should I 
use a hose instead of copper tubing (Iâ??m thinking it might work-harden then 
break due to the vibration).

If I do need hose, Iâ??m looking at some PTFE, stainless braid covered fuel 
line.  It is rated for 2500 PSI working pressure, 8000 PSI burst pressure, and 
450F temp, so it would seem up to the job.

I will also mount a water trap with an automatic drain between the radiator and 
the tank, and since that will all be upstream of the unloader valve, it will 
drain each time the compressor cycles off.  Iâ??ve found two kinds of traps, 
one that is basically a container that would go on the end of a drip leg, and 
one that all the air passes through.  Any thoughts if one would be more 
effective than the other?  It would seem like passing all the air through would 
be better, as some water could make the bend with a drip leg.

Thanks,
Darrell

PS Sorry if this gets posted twice, I sent it the first time from the wrong 
email account
_______________________________________________

Shop-talk@autox.team.net
Donate: http://www.team.net/donate.html
Suggested annual donation  $12.96
Archive: http://www.team.net/pipermail/shop-talk http://autox.team.net/archive

Unsubscribe/Manage: 
http://autox.team.net/mailman/options/shop-talk/mharc@autox.team.net

<Prev in Thread] Current Thread [Next in Thread>