> Sort of. POTS single-line phones will work fine on T568B. Two line
> phones may, or may not. It depends on how the cross connect stuff is
> done.
I'm not following you here, David. Even with a 2-line phone, as long as the
patch cords are wired 1-1, they should not care which wire is paired with
which wire. That has been true even for the multi-line digital signaling
systems I've worked with. The only real difference between 568A termination
and 568B termination is the color of the pairs ... can your phones see in
color?
<G>
> If you're doing a new installation, go with T568A. There's very
> little reason not to; it's the preferred solution, and I expect T568B
> will eventually die.
I presume you mean the 568A termination, rather than the obsolete 568A
standard. The old standard didn't even mention Cat 5e, let alone Cat 6.
However EIA-568-B recommends using the 568A termination.
Randall