To: | David Scheidt <dmscheidt@gmail.com> |
---|---|
Subject: | Re: Maintenance |
From: | Doug Braun <doug@dougbraun.com> |
Date: | Tue, 26 Dec 2006 20:42:21 -0800 (PST) |
That's not really the safety valve- its purpose is to bleed out the pressure in the line from the pump to the tank (there is a check valve at the tank entrance to keep the tank air from escaping). It is open whenever the pressure switch has turned off the motor. The pressure has to be removed from the line so that the motor will not have to start up with a full load from the compressor. Doug --- David Scheidt <dmscheidt@gmail.com> wrote: > The safety valve on my compressor opens for about 10 > seconds every > time the compressor shuts off. I figured that was > on purpose? > -- |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: Maintenance, David Scheidt |
---|---|
Next by Date: | RE: Maintenance, Randall |
Previous by Thread: | Re: Maintenance, David Scheidt |
Next by Thread: | RE: Maintenance, Randall |