Gary, the pull in coil is nominally 0.5 ohms and the hold coil is 12 ohms.
At 12 volts, the pull-in coil should draw 24 amps and the hold coil 1 amp.
The pull-in coil normally operates for only a brief time, so I have used a
20A fuse in the circuit for several years without a problem.  Actually, I
believe it did blow once, but a replacement did not.  Transient spike, I
assume.  
50A seems a bit high to me, too.

Steve Byers
HBJ8L/36666
BJ8 Registry
Havelock, NC  USA

-----Original Message-----
From: healeys-bounces@autox.team.net [mailto:healeys-bounces@autox.team.net]
On Behalf Of warthodson@aol.com
Sent: Saturday, January 28, 2012 10:38 AM
To: healeys@autox.team.net
Subject: [Healeys] OD Solenoid

I cannot find the current draw of the OD Solenoid, can someone help me? I am
interested in both the holding circuit draw & the pull-in circuit draw. Norm
Knock's Tech Talk book recommends fusing the OD circuit at 50 amps which
seems very high, but what do I know?
Gary Hodson