Earl Kagna wrote:

>Due respect Rich, the Healey heater blower motor is a permanent magnet 
>motor - doesn't care about polarity.  I have converted at least a half dozen 
>Healeys to NEG ground, including my present two, without interchanging the 
>blower motor wires - they've all continued to move air in the right 
>direction.
>  
>
Earl, there's been a misunderstanding somewhere -- permanent magnet DC
motors do reverse rotation with polarity.  As has been pointed, because
it's a centrifugal blower, it will move air regardless of the direction
of motor rotation, HOWEVER, it will move air ever so much better when
the rotation is in the correct direction.
-- 