Hi Barry

In the stock series V Alpine alternator circuit, there is no 
switching relay.   There is the 4TRregulator and the warning light simulator.

The high current lead goes directly to the starter circuit 
selonide, where it ties into the battery circuit.

Are you refering to the starter solonide?  While the 10AC is only rated for 
35 Amps  the starter relay has to be rated for more than 100A of 
cranking current.  

Steve F

*******************************************************************************
Steve Finberg                        W1GSL                       w1gsl@mit.edu
PO Box 397082 MIT Br        Cambridge MA  02139-7082              617 258 3754
*******************************************************************************