To: | trguy@cfl.rr.com, 6pack@Autox.Team.Net |
---|---|
Subject: | Re: Dizzy Question |
From: | DaCRANEz@aol.com |
Date: | Mon, 29 Nov 2004 00:19:16 EST |
The 41352 model was specific to the 1971 model year. I has a different advance curve than your earlier unit. The static timing for the 41202 is 12 deg BTDC and for the 41352 is 4 deg BTDC. They both call for dynamic timing of 4 deg ATDC with vacuum retard blocked. The big difference is in the cetrifigal advance curves. At 3000 rpm the maximum advance on the 41202 is 22 deg at the crank versus 30 degrees for 41352. You may run into an over advance problem with the 41352. Others may be able to elabotate more on this subject. I know that Berry Price sleeved his posts to limit advance. There is much detailed info in the Bentley Manual-pp.511 thru 517.Hope this helps. Mike C '71 TR6 |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: Whole Bunch of TR250 stuff going on, Ed Bratt |
---|---|
Next by Date: | Re: Dizzy Question, Greg Dito |
Previous by Thread: | Re: Dizzy Question, Sally or Dick Taylor |
Next by Thread: | Re: Dizzy Question, Greg Dito |
Indexes: | [Date] [Thread] [Top] [All Lists] |