>Have you tried connecting together the two wires
that go to the switch? <

Yes, that is the test.  Do you happen to be using Dot5 fluid?  It seems that 
silicon fluid leakage causes high resistance.  I have had two switches fail 
in the mode where it kept taking more and more pressure to get them to turn 
on.  The contacts were getting wet with the silicon fluid - which is a great 
insulator!