Unless this is a large, complex system, I think the simplest and effective
way to deal with moisture in the piping is iron piping with drip stems with
ball valves on the ends and a moisture separator near each air outlet, and
each outlet needs to be stubbed off of a vertical pipe section. I just
google air system pipe layout and that many layouts, most using this basic
idea.