| Subject: | [Shop-talk] Plasma Cutter- the review |
|---|---|
| From: | tr3driver at ca.rr.com (Randall) |
| Date: | Fri, 14 Jan 2011 13:30:48 -0800 |
| References: | <788978.26692.qm@web82406.mail.mud.yahoo.com> <OFAC9B4B16.AAF35588-ON85257818.0074816F-85257818.007499FB@mail.megageek.com> |
> The air requirements are very little. In fact, they just say between > 50psi and 70 psi. There is no cfps requirement on it. The maker's website gives 3.5 cfm: http://ramsond.com/proddetail.php?prod=CUT50DY It doesn't really specify whether that is 3.5 scfm (ie 3.5 cf after expanding to 1 atmosphere) or acfm (actual 3.5 cf of compressed air), but usually air tools are given as inlet acfm, meaning it needs roughly 17 scfm (at 4 atmospheres/60 psi). -- Randall |