     I don't know of any quartz clock that would draw .2A.  If your system is
really drawing that much current when 'shut down', something's amiss.  That's
about 3 amp-hours/day, 100 amp-hours/month.  Do you have an alarm system that's
drawing power?

Bud Krueger
52TD

Scott Allen wrote:

> Hi,
>
> As some of y'all may remember I had a problem with the volt. regulator on my
> TD back in November.  At the time I had replaced it because my battery was
> dying, and testing indicated the old one was drawing current when the car
> wasn't running, or rather it was determined that the points in the reg
> weren't operating properly.  Replacing it fixed the problem.
>
> So I try and fire up the TD last PM, (five months and 800 miles later) and
> the battery's dead.  Testing today at indicates the charging system's
> behaving as follows:
>
> RPM           Volts @ Generator & Battery     Ammeter Reading
>
> 1200, (idle)          12.06                      -1 or so
>
> 2000                  13                         10-15
>
> 2500                  13.5                       15-22
>
> When the car's shut down I have a miniscule draw, (.2- of an amp) which I
> think is probably the quartz movement in the clock.
>
> Oh yeah, I have the 5-post reg..
>
> So I'm wondering if the above is "normal" and if so maybe I'm dealing with
> the transient open points issue again, which considering that both regs came
> from the same source may be a possibility.
>
> Any info appreciated,
>
> Scott Allen