On Friday, May 07, 2010 04:53:12 pm wbeech@flash.net wrote:
> Hello List,
>
> Having some problems with erratic readings from my new sending unit
> recently acquired from BPNW. I have checked everything to be sure the
> connections are tight, even ran an additional ground wire from the gauge
> to the dash panel.
>
> Still no improvement, so I wrote to BPNW and they say I should have a
> Voltage Stabilizer pn=148876D mounted behind the gauges. I don't recall
> anything like this in any TR3 documentation. When I look this part up on
> the BPNW web site it shows to be an MG part, but BPNW insists this is what
> I should have for the Triumph.
>
>
>
> Has anyone installed one of these on a TR3?
>
> http://www.bpnorthwest.com/.sc/ms/bdd/ee/9955/Voltage%20Stabilizer
> <http://www.bpnorthwest.com/.sc/ms/bdd/ee/9955/Voltage%20Stabilizer>
>
>
> Bill Beecher
>
Bill,
The voltage stabilizer is standard equipment on TR4 and up but not on the 3.
I did install a 4 version on my 3 because I use the TR4 temperature sender and
gauge. My fuel sensor and gauge are stock TR3 and do not use the stabilizer.
If you think you need a stabilizer, look at the TR4 wiring diagram in order to
get instructions on wiring but I think you would need a TR4 fuel gauge.
Bob