> When setting the float level on the SU H6 carb, the manual
> says to pass a
> 7/16" rod between the float level aluminum forked lever and
> the inverted lid.
> However, when this is done does this mean the needle
> completely shuts off
> (with the mimicing of fuel by one's breath). Or does it
> mean, 'that at
> 7/16"ths the fuel level just begins to stop' or other?
Paul, I don't actually think it's all that critical. Small errors in float
level don't seem to cause a problem.
But I take it to mean that the valve should be closed (unable to blow
through it), with the fork dragging on the rod (on both sides).