triumphs
[Top] [All Lists]

Re: Journal measurements (Bentley manual)

To: "Jim Barbuscia" <jimbar@centurytel.net>,
Subject: Re: Journal measurements (Bentley manual)
From: "Graham Stretch" <technical-iwnet@wight365.net>
Date: Mon, 3 Jan 2005 23:16:32 -0000
Hi Jim
Serious Typo!!!
I don't know if you got help or replies for this, I don't see any but you
probably got some off list! In case you didn't here are the specs from my
2.5PI repair operations manual.
Journals      2.3110 - 2.3115
Crank pins  1.8750 - 1.8755
I hope this is not too late to be of help to you, I was just catching up on
some back postings!

Graham.

----- Original Message ----- 
From: "Jim Barbuscia"
Subject: Journal measurements (Bentley manual)


> Hi All,
> I see in my Bently manual the TR6 standard crank measurements are as
> follows: Main= 2.3110/2.3315 and Rod= 1.8750/1.8755 . My question is why
> do the mains get over .020 from min. to max. clearance and the rods only
> .0005 min to max diff. ? or is there a typo in the manual? if so what
> are the real journal measurements?
>
> Help!
>
> -jimb



---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.825 / Virus Database: 563 - Release Date: 30/12/2004