Cliff :

It's very easy to have 0.5 ohms (or more) contact and lead resistance with 
standard probes.  Try taking a measurement with both probes on the same lead, 
then difference that with the reading across the coil.  The result is still 
only going to be good to a few tenths, but it should be better than what you 
are doing now.

To really get an accurate reading, you need a 4-lead meter, or a calibrated 
current source.

Randall


On Tuesday, September 05, 2000 5:03 PM, Cliff Hansen [SMTP:hansenc@flash.net] 
wrote:
>
> Hi,
>
> Everyone must have an LBC support vehicle - this question is
> about mine and that's the extent of the LBC content.
>
> I'm using a digital ohmmeter to check the coil in my Mazda truck.
> Is there any reason that the meter will read high when testing the
> primary windings?  1.4 ohm instead of the .9 ohm spec.
> If not then I may have found my elusive sluggish, lack-of-power
> problem.
>
> Thanks.
>
> Cliff Hansen