<<<This coil takes 15 amps, and is not intended for continuous use. The solenoid plunger needs to travel far enough to activate the internal switch that turns on the holding coil and cuts off the closing coil. The holding coil uses less than one amp.>>> A slight correction. Both coils are energized when the solenoid is first activated. The internal switch shuts off the closing coil only. Still in Daly City |