Thanks Ron for the current draw spec. Very good information
Jim A
In a message dated 1/19/2016 5:24:14 P.M. Eastern Standard Time,
rfraser@bluefrog.com writes:
Jim
The blower motor on my Tiger was running slow at one time. I found
that the motor was drawing over 1 amp. The motor bushings were seized to the
motor.
I cleaned the motor shaft and lubed the bushings. The blower ran much
better and only drew around .1 amp. I don't recall exactly what the final amp
draw was, too long ago. Checking the amp draw is one way of checking the
motor/ bushing condition.
The heater core is sized nicely IMO.
You have to check that the core is not plugged - I back flush the core now
and then to get the sediment out of it.
The air has to go through the core not around it for it to work correctly.
Ron Fraser
-----Original Message-----
From: Tigers [mailto:tigers-bounces@autox.team.net] On Behalf Of
Rollright--- via Tigers
Sent: Tuesday, January 19, 2016 3:02 PM
To: tigers@autox.team.net
Subject: Re: [Tigers] Blower/Heater
Hello,
Though my Tiger 1A is tucked away for the Massachusetts winter, thoughts
of improvements/fix-ups still pass through my head. This question is about
the anemic demister/heater system.
Two components make up this system
1) the blower with the squirrel cage fan
2) the heater radiator
The blower fan seems like it could use a redesign. SOOOO slow. Mine is
working same as it ever was. Anybody tried upgrading this?
The radiator seems awfully small. Any smart-guy thoughts on this?
Anything else I should be thinking of? Any Ideas?
Even if the heater isn't regularly used, I'd like to be able to count on
the system to defog the windshield.
Jim Armstrong
382002083
Mk 1A
code 86
TAC # 0763
--part1_90fae2.346a766.43d0f49b_boundary
Content-Transfer-Encoding: quoted-printable
<!DOCTYPE HTML PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN">
<HTML><HEAD>
<META content=3D"text/html; charset=3DUS-ASCII" http-equiv=3DContent-Type>
<META name=3DGENERATOR content=3D"MSHTML 11.00.9600.18163"></HEAD>
<BODY id=3Drole_body style=3D"FONT-SIZE: 10pt; FONT-FAMILY: Arial; COLOR:=
#000000"=20
bottomMargin=3D7 leftMargin=3D7 rightMargin=3D7 topMargin=3D7><FONT id=3Dr=
ole_document=20
color=3D#000000 size=3D2 face=3DArial>
<DIV>Thanks Ron for the current draw spec. Very good information</DIV>
<DIV> </DIV>
<DIV>Jim A</DIV>
<DIV> </DIV>
<DIV>
<DIV>In a message dated 1/19/2016 5:24:14 P.M. Eastern Standard Time,=20
rfraser@bluefrog.com writes:</DIV>
<BLOCKQUOTE=20
style=3D"PADDING-LEFT: 5px; MARGIN-LEFT: 5px; BORDER-LEFT: blue 2px solid"=
><FONT=20
style=3D"BACKGROUND-COLOR: transparent" color=3D#000000 size=3D2 face=3D=
Arial>
<DIV><SPAN class=3D078291422-19012016>Jim</SPAN></DIV>
<DIV><SPAN class=3D078291422-19012016> The blower moto=
r on my=20
Tiger was running slow at one time. I found that the motor was dra=
wing=20
over 1 amp. The motor bushings were seized to the motor.</SPAN></D=
IV>
<DIV><SPAN class=3D078291422-19012016>I cleaned the motor shaft and lube=
d the=20
bushings. The blower ran much better and only drew around .1 amp.&=
nbsp;=20
I don't recall exactly what the final amp draw was, too long ago. &=
nbsp;=20
Checking the amp draw is one way of checking the motor/ bushing=20
condition.</SPAN></DIV>
<DIV><SPAN class=3D078291422-19012016></SPAN> </DIV>
<DIV><SPAN class=3D078291422-19012016> The heater core=
is=20
sized nicely IMO.</SPAN></DIV>
<DIV><SPAN class=3D078291422-19012016>You have to check that the core is=
not=20
plugged - I back flush the core now and then to get the sediment out of=
=20
it.</SPAN></DIV>
<DIV><SPAN class=3D078291422-19012016>The air has to go through the core=
not=20
around it for it to work correctly.</SPAN></DIV>
<DIV><SPAN class=3D078291422-19012016></SPAN> </DIV>
<DIV><SPAN class=3D078291422-19012016>Ron Fraser</SPAN></DIV>
<DIV><SPAN class=3D078291422-19012016></SPAN> </DIV>
<DIV><SPAN class=3D078291422-19012016></SPAN> </DIV>
<DIV><SPAN class=3D078291422-19012016></SPAN>
<DIV></DIV><FONT face=3DTahoma><FONT face=3DArial><SPAN=20
class=3D078291422-19012016> </SPAN></FONT>-----Original=20
Message-----<BR><B>From:</B> Tigers [mailto:tigers-bounces@autox.team.ne=
t]=20
<B>On Behalf Of </B>Rollright--- via Tigers<BR><B>Sent:</B> Tuesday, Jan=
uary=20
19, 2016 3:02 PM<BR><B>To:</B> tigers@autox.team.net<BR><B>Subject:</B>=
Re:=20
[Tigers] Blower/Heater<BR><BR></FONT></DIV>
<BLOCKQUOTE style=3D"MARGIN-RIGHT: 0px" dir=3Dltr><FONT face=3DArial>
<DIV>Hello,</DIV>
<DIV> </DIV>
<DIV>Though my Tiger 1A is tucked away for the Massachusetts wint=
er,=20
thoughts of improvements/fix-ups still pass through my head. This ques=
tion=20
is about the anemic demister/heater system.</DIV>
<DIV> </DIV>
<DIV>Two components make up this system</DIV>
<DIV>1) the blower with the squirrel cage fan</DIV>
<DIV>2) the heater radiator</DIV>
<DIV> </DIV>
<DIV>The blower fan seems like it could use a redesign. SOOOO slo=
w.=20
Mine is working same as it ever was. Anybody tried=20
upgrading this?</DIV>
<DIV>The radiator seems awfully small. Any smart-guy thoughts on this?=
</DIV>
<DIV> </DIV>
<DIV>Anything else I should be thinking of? Any Ideas?</DIV>
<DIV> </DIV>
<DIV>Even if the heater isn't regularly used, I'd like to be able to=
count=20
on the system to defog the windshield.=20
<DIV> </DIV>
<DIV><FONT lang=3D0 face=3DArial PTSIZE=3D"10" FAMILY=3D"SANSSERIF">Ji=
m=20
Armstrong<BR>382002083<BR>Mk 1A<BR>code 86<BR>TAC #=20
0763</FONT></DIV></DIV></FONT></BLOCKQUOTE></FONT></BLOCKQUOTE></DIV><=
/FONT></BODY></HTML>
--part1_90fae2.346a766.43d0f49b_boundary--
--===============4228566266763178900==
Content-Transfer-Encoding: 7bit
Content-Disposition: inline
_______________________________________________
tigers@autox.team.net
Archive: http://www.team.net/archive
Unsubscribe: http://autox.team.net/mailman/options/tigers/mharc@autox.team.net
--===============4228566266763178900==--
|