To: Jim Stone <1789alpine@gmail.com> 2903e8d5c8f:6.0.391,18.0.790,17.0.607.475.0000000 definitions=2021-08-21_08:2021-08-20_03,2021-08-21_08,2020-04-07_01 signatures=0 adultscore=0 malwarescore=0 bulkscore=0 spamscore=0 mlxscore=0 suspectscore=0 clxscore=1015 phishscore=0 classifier=spam adjust=0 reason=mlx scancount=1 engine=8.12.0-2009150000 definitions=main-2108210116
Subject: Re: [Shop-talk] LP Generator supply
From: Pat Horne <patintexas@icloud.com>
Date: Sat, 21 Aug 2021 13:39:05 -0500
Cc: Shop Talk <shop-talk@autox.team.net>
Delivered-to: mharc@autox.team.net
Delivered-to: shop-talk@autox.team.net
References: <027899F9-876C-4CD0-8A43-33F46A324516@gmail.com>
--===============2483302489767674569==
Content-Transfer-Encoding: 7bit


--Apple-Mail-E5732877-BB93-4B4E-ABAB-4E6CBB5B4886
        charset=utf-8
Content-Transfer-Encoding: quoted-printable

Oh, & good luck with the storm.=20

Peace,
Pat

Pat Horne=20
We support Habitat for Humanity


On Aug 21, 2021, at 1:08 PM, Jim Stone <1789alpine@gmail.com> wrote:

=EF=BB=BFI am on Eastern Long Island, directly in one of the projected paths=
 of Hurricane Henri.  We are being told to plan for 7-10 days without power,=
 although FWIW we were only powerless for 4 days following Sandy.  Shortly a=
fter Sandy I purchased an LP Generator (https://www.jbtools.com/buffalo-tool=
s-gen4000lp-4000-watt-propane-generator/?wi=3Doff&gclid=3DCjwKCAjwyIKJBhBPEi=
wAu7zll1U54VH4euJneVO0jmOzjdgwy6-t0MUdEtaEHYXf_7W0sQxKo54TphoC__4QAvD_BwE) w=
hich, of course, I have never needed, although I do run it periodically to b=
e safe.  It is designed to run off of LP tanks and comes with a standard reg=
ulator.  A little Googling shows the following specs for the regulator:

Low Pressure Regulator
Inlet Pressure:               25-250PSIG
Outlet Pressure:            280mmH2O=3D (11"W.C.)
Flow Capacity(MAX):    119000(BTU/hr)

We use Propane for DHW and heat and have a 500 gallon in-ground tank.   I ha=
d an outside gas line stubbed out when the house was remodeled, just in case=
 I ever needed it and I would like to be able to connect the generator direc=
tly to the house supply and avoid having to depend on the portable tanks.  T=
he house supply is regulated and, as an example, here are the specs for the w=
ater heater:

Max Inlet Gas Pressure:    13.0 =E2=80=9CW.C.
Min Inlet Gas Pressure:     8.0 =E2=80=9CW.C.
Recovery Rating:               206/Gallons/HR
Max Working Pressure:     150psi
Max Output:                       180,000 BTU/HR
Max Input:                          11,000 BTU/HR
Manifold Pressure:             3.9 =E2=80=9CW.C. (For Max Input)

Am I missing anything, or should I be able to hook the generator directly to=
 the house supply without the regulator?  For the record, I tried it once wi=
th the regulator attached and it barely ran and didn=E2=80=99t put out any a=
ppreciable power.  I always meant to research this before I needed it, but l=
ike many of us, never got around to it until now.

Thanks,
Jim


_______________________________________________

Shop-talk@autox.team.net
Archive: http://www.team.net/pipermail/shop-talk http://autox.team.net/archi=
ve

as@icloud.com


--Apple-Mail-E5732877-BB93-4B4E-ABAB-4E6CBB5B4886
        charset=utf-8
Content-Transfer-Encoding: quoted-printable

<html><head><meta http-equiv=3D"content-type" content=3D"text/html; charset=3D=
utf-8"></head><body dir=3D"auto">Oh, &amp; good luck with the storm.&nbsp;<d=
iv><br></div><div>Peace,</div><div>Pat<br><br><div dir=3D"ltr">Pat Horne&nbs=
p;<div>We support Habitat for Humanity</div><div><br></div></div><div dir=3D=
"ltr"><br>On Aug 21, 2021, at 1:08 PM, Jim Stone &lt;1789alpine@gmail.com&gt=
; wrote:<br><br></div><div dir=3D"ltr">=EF=BB=BF<meta http-equiv=3D"Content-=
Type" content=3D"text/html; charset=3Dutf-8">I am on Eastern Long Island, di=
rectly in one of the projected paths of Hurricane Henri. &nbsp;We are being t=
old to plan for 7-10 days without power, although FWIW we were only powerles=
s for 4 days following Sandy. &nbsp;Shortly after Sandy I purchased an LP Ge=
nerator (<a href=3D"https://www.jbtools.com/buffalo-tools-gen4000lp-4000-wat=
t-propane-generator/?wi=3Doff&amp;gclid=3DCjwKCAjwyIKJBhBPEiwAu7zll1U54VH4eu=
JneVO0jmOzjdgwy6-t0MUdEtaEHYXf_7W0sQxKo54TphoC__4QAvD_BwE" class=3D"">https:=
//www.jbtools.com/buffalo-tools-gen4000lp-4000-watt-propane-generator/?wi=3D=
off&amp;gclid=3DCjwKCAjwyIKJBhBPEiwAu7zll1U54VH4euJneVO0jmOzjdgwy6-t0MUdEtaE=
HYXf_7W0sQxKo54TphoC__4QAvD_BwE</a>) which, of course, I have never needed, a=
lthough I do run it periodically to be safe. &nbsp;It is designed to run off=
 of LP tanks and comes with a standard regulator. &nbsp;A little Googling sh=
ows the following specs for the regulator:<div class=3D""><br class=3D""></d=
iv><div class=3D""><ul class=3D"MailOutline"><li class=3D"">Low Pressure Reg=
ulator</li><li class=3D"">Inlet Pressure: &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;=
 &nbsp; &nbsp; 25-250PSIG</li><li class=3D"">Outlet Pressure: &nbsp; &nbsp; &=
nbsp; &nbsp; &nbsp; &nbsp;280mmH2O=3D (11"W.C.)</li><li class=3D"">Flow Capa=
city(MAX): &nbsp; &nbsp;119000(BTU/hr)</li></ul><div class=3D""><br class=3D=
""></div></div><div class=3D"">We use Propane for DHW and heat and have a 50=
0 gallon in-ground tank. &nbsp; I had an outside gas line stubbed out when t=
he house was remodeled, just in case I ever needed it and I would like to be=
 able to connect the generator directly to the house supply and avoid having=
 to depend on the portable tanks. &nbsp;The house supply is regulated and, a=
s an example, here are the specs for the water heater:</div><div class=3D"">=
<br class=3D""></div><div class=3D""><ul class=3D"MailOutline"><li class=3D"=
">Max Inlet Gas Pressure: &nbsp; &nbsp;13.0 =E2=80=9CW.C.</li><li class=3D""=
>Min Inlet Gas Pressure: &nbsp; &nbsp; 8.0 =E2=80=9CW.C.</li><li class=3D"">=
Recovery Rating: &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; 206/Gallon=
s/HR</li><li class=3D"">Max Working Pressure: &nbsp; &nbsp; 150psi</li><li c=
lass=3D"">Max Output: &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp=
; &nbsp; &nbsp; &nbsp; 180,000 BTU/HR</li><li class=3D"">Max Input: &nbsp; &=
nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &=
nbsp;11,000 BTU/HR</li><li class=3D"">Manifold Pressure: &nbsp; &nbsp; &nbsp=
; &nbsp; &nbsp; &nbsp; 3.9 =E2=80=9CW.C. (For Max Input)</li></ul><div class=
=3D""><br class=3D""></div><div class=3D"">Am I missing anything, or should I=
 be able to hook the generator directly to the house supply without the regu=
lator? &nbsp;For the record, I tried it once with the regulator attached and=
 it barely ran and didn=E2=80=99t put out any appreciable power. &nbsp;I alw=
ays meant to research this before I needed it, but like many of us, never go=
t around to it until now.</div><div class=3D""><br class=3D""></div><div cla=
ss=3D"">Thanks,</div><div class=3D"">Jim</div><div class=3D""><br class=3D""=
></div></div><div class=3D""><br class=3D""></div><span>____________________=
___________________________</span><br><span></span><br><span>Shop-talk@autox=
.team.net</span><br><span>Donate: http://www.team.net/donate.html</span><br>=
<span>Suggested annual donation &nbsp;$12.96</span><br><span>Archive: http:/=
/www.team.net/pipermail/shop-talk http://autox.team.net/archive</span><br><s=
pan></span><br><span>Unsubscribe/Manage: http://autox.team.net/mailman/optio=
ns/shop-talk/patintexas@icloud.com</span><br><span></span><br></div></div></=
body></html>=

--Apple-Mail-E5732877-BB93-4B4E-ABAB-4E6CBB5B4886--

--===============2483302489767674569==
Content-Transfer-Encoding: 7bit
Content-Disposition: inline

_______________________________________________

Shop-talk@autox.team.net
Archive: http://www.team.net/pipermail/shop-talk http://autox.team.net/archive



--===============2483302489767674569==--

<Prev in Thread] Current Thread [Next in Thread>