I believe that is what they did when I put a subpanel in the small shed I
have for my pool pumps. They removed the bonding bar.
-----Original Message-----
From: shop-talk-bounces at autox.team.net
[mailto:shop-talk-bounces at autox.team.net] On Behalf Of Wayne
Sent: Thursday, March 08, 2012 10:52 PM
To: Shop Talk List
Subject: Re: [Shop-talk] Running power to the shop
>> The electrician did mention ground rods at the sub-panel. I forgot
>> to add that, my bad.
That sounds TOTALLY wrong. I flunked out of EE and am not a licensed
electrician. But AFAIK, the neutral and ground should be "bonded" at ONE
point and ONE POINT ONLY. A subpanel should have a separate neutral and
ground wire run to it, and the bonding bar between the the two in the box
should be removed, to create an "isolated ground" whereas a main entrance
panel has the two connected.
-Wayne