shop-talk
[Top] [All Lists]

Re: [Shop-talk] Electrical Outlet wiring question

To: Steven Trovato <strovato@optonline.net>
Subject: Re: [Shop-talk] Electrical Outlet wiring question
From: David Scheidt <dmscheidt@gmail.com>
Date: Fri, 12 Mar 2010 17:50:01 -0500
On Fri, Mar 12, 2010 at 5:44 PM, Steven Trovato <strovato@optonline.net>wrote:

> Peter,
> I don't think that is correct.  My house has two outlet circuits wired with
> a single run of 14-3 Romex and a 220 breaker.  Some outlets use one side of
> the 220, some use the other.  But they all use the common neutral.  This was
> reasonably common practice to save wire, and met the code, at least 25 years
> ago when my house was built.


It's still common where there are long runs, or limited space in raceways or
conduit.


-- 
David Scheidt