When we moved into our house, I tried by compressor in the 15A outlet in
the garage and it tripped the breaker.  I also tried my MIG welder and 
the welds didn't penetrate at all.  You know, when the breaker trips, 
you find out how many other outlets and lights are on that same circuit.
  Hmmm.  Since the welder is 110V, I decided to run 12AWG wire from a 
20A breaker to a 20A outlet in the attached garage.  It's one run to one
outlet, do not pass go, do not collect $200.  The compressor jumps to 
life when started even in the winter.  The welds are sloppy and 
sometimes burn through, but that's my fault, not the power.  Before I 
finish the basement I might run a 220V line for the compressor in case 
it wanted to cycle while I'm welding.   

Oh, one thing my father taught me put the compressor next to the outlet 
and run a long hose.  No extension cords! 
 

-------------------------------------------------------------------------