FWIW, a Lincoln "tombstone" welder wants 50 amps, I think a Lincoln TOG 175
wants
about the same, and my new HTP Inverter Tog only asks for 25A on a 240v line.
MIG
welders are all over the lot. I run an oven for powder coating on a 30A line
(oven only, including the self cleaning feature) where normally a stove is on a
50A line. And my 5hp compressor (a real 5hp) runs on a 20A line.
I guess it depends on what your aspirations are.
Jim
MJSUKEY@cs.com wrote:
> Still working on planing on finishing the garage. A second question if you
> don't mind. While I am running wire and before I put up drywall I am
> thinking I would like to run (2) 240 volt circuits while the walls are open
> thinking that someday I might purchase some kind of toys that would need 240
> (air comp, welder, ?????). Since I don't know the amp requirement of this
> future purchase I am unsure as to what gauge wire to run. # 10 for 30 amp,
> #8 for 40 amp seem to be the ballpark I would need. Any thoughts on this one?
>
> Thanks again,
> Marty Sukey