>Thanks to all who have offered help so far.
>
>I have found some problems with the distributor (small braided wire was
>toast - replaced, other wire to LT terminal was not soldered in,
>repaired) and have 12v at the points now. BUT, still no spark at coil or
>plugs (had weak spark from coil for a bit, gone now).
>
>I am now waiting for another "new" capacitor, hoping that will be the
>last problem (Nory was right!)
>
Hmmm, last time it happened to me it turned out to be the distributor 
cap. No obvious flaws, just old with a lot of carbon buildup on the 
inside. In damp weather, after a few days of slightly hard starting, one 
morning - fzzzzt! nothing. My sage advisor said, "replace the cap and 
rotor", and that did it. Don't know that this matches your symptoms, but 
FWIW.



Max Heim
'66 MGB
runs great, needs paint
Palo Alto CA