Listers
About a month ago I posted to the list looking for a verification of a CFM =
calculation of the stock 4 blade fan on a 100. =20
Bill Atterbury responded that my numbers looked like they were off by a fac=
tor of 10. Bill was correct.=20
After revisiting the question it looks like the CFM should be approximately=
:
Fan specs: Pitch=3D 1-1/8 inch=20
Overall diameter=3D14.75 inches=20
CFM @ 700 RPM =3D310 CFM
CFM @1000 RPM =3D444 CFM
CFM @4000 RMP=3D 1776 CFM
So if you wonder why a small 12 inch electric fan that puts out 1250 CFM (F=
lexALite#111) seems to cool the 100 a lot better at idle
this may help to explain it, unless of course I have made another mistake.=
=20
Thanks
Perry
Sent from Mail for Windows 10
--_EAF6C623-C8B6-4F39-A368-2A4611EC297A_
Content-Transfer-Encoding: quoted-printable
<html xmlns:o=3D"urn:schemas-microsoft-com:office:office" xmlns:w=3D"urn:sc=
hemas-microsoft-com:office:word" xmlns:m=3D"http://schemas.microsoft.com/of=
fice/2004/12/omml" xmlns=3D"http://www.w3.org/TR/REC-html40"><head><meta ht=
tp-equiv=3DContent-Type content=3D"text/html; charset=3Dutf-8"><meta name=
=3DGenerator content=3D"Microsoft Word 15 (filtered medium)"><style><!--
/* Font Definitions */
@font-face
{font-family:"Cambria Math";
panose-1:2 4 5 3 5 4 6 3 2 4;}
@font-face
{font-family:Calibri;
panose-1:2 15 5 2 2 2 4 3 2 4;}
/* Style Definitions */
p.MsoNormal, li.MsoNormal, div.MsoNormal
{margin:0in;
margin-bottom:.0001pt;
font-size:11.0pt;
font-family:"Calibri",sans-serif;}
a:link, span.MsoHyperlink
{mso-style-priority:99;
color:blue;
text-decoration:underline;}
.MsoChpDefault
{mso-style-type:export-only;}
@page WordSection1
{size:8.5in 11.0in;
margin:1.0in 1.0in 1.0in 1.0in;}
div.WordSection1
{page:WordSection1;}
--></style></head><body lang=3DEN-US link=3Dblue vlink=3D"#954F72"><div cla=
ss=3DWordSection1><p class=3DMsoNormal>Listers</p><p class=3DMsoNormal>Abou=
t a month ago I posted to the list looking for a verification of a CFM calc=
ulation of the =C2=A0stock 4 blade fan on a 100.=C2=A0 =C2=A0</p><p class=
=3DMsoNormal>Bill Atterbury responded that my numbers looked like they were=
off by a factor of 10. Bill was correct. </p><p class=3DMsoNormal>After re=
visiting the question it looks like the CFM should be approximately:</p><p =
class=3DMsoNormal>Fan specs: =C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=
=A0=C2=A0 Pitch=3D 1-1/8 inch <o:p></o:p></p><p class=3DMsoNormal style=3D'=
margin-left:.5in;text-indent:.5in'>Overall diameter=3D14.75 inches <o:p></o=
:p></p><p class=3DMsoNormal>CFM @ 700 RPM =3D310 CFM<o:p></o:p></p><p class=
=3DMsoNormal>CFM @1000 RPM =3D444 CFM<o:p></o:p></p><p class=3DMsoNormal>CF=
M @4000 RMP=3D 1776 CFM<o:p></o:p></p><p class=3DMsoNormal><o:p> </o:p=
></p><p class=3DMsoNormal>So if you wonder why a small 12 inch electric fan=
that puts out 1250 CFM (FlexALite#111) seems to cool the 100 a lot better =
at idle<o:p></o:p></p><p class=3DMsoNormal>this may help to explain it, unl=
ess of course I have made another mistake. <o:p></o:p></p><p class=3DMsoNor=
mal>Thanks<o:p></o:p></p><p class=3DMsoNormal>Perry</p><p class=3DMsoNormal=
><o:p> </o:p></p><p class=3DMsoNormal>Sent from <a href=3D"https://go.=
microsoft.com/fwlink/?LinkId=3D550986">Mail</a> for Windows 10</p><p class=
=3DMsoNormal><o:p> </o:p></p></div></body></html>=
--_EAF6C623-C8B6-4F39-A368-2A4611EC297A_--
--===============1387706305159767574==
Content-Transfer-Encoding: 7bit
Content-Disposition: inline
_______________________________________________
Archive: http://www.team.net/pipermail/healeys http://autox.team.net/archive
Healeys@autox.team.net
http://autox.team.net/mailman/listinfo/healeys
--===============1387706305159767574==--
|