Mike, I don't know the nominal resistance of the relay coil, but the
solenoid has two coils -- the "pull-in" coil and the "holding coil".  The
pull-in coil should be 0.5 ohms and the holding coil 12 ohms.

What problems are you having with the overdrive?

Steve Byers
HBJ8L/36666
BJ8 Registry
Havelock, NC  USA

-----Original Message-----
From: healeys-bounces@autox.team.net [mailto:healeys-bounces@autox.team.net]
On Behalf Of Mike Garvey
Sent: Wednesday, May 29, 2013 6:50 PM
To: healeys@autox.team.net
Subject: [Healeys] BJ8 Overdrive Electrical

I am troubleshooting electrical issues with my overdrive; does anyone know
the nominal resistance (ohms) of the coil in the relay (on the firewall) and
the resistance of the solenoid? 

Thanks, Mike 

 

Michael Garvey

1967 BJ8/38046

Swampscott, MA