Subject: | [Healeys] Chasing Electrical Short--- SOLVED! |
---|---|
From: | bjsbj8 at gmail.com (Bob Johnson) |
Date: | Tue, 24 Apr 2012 15:14:11 -0400 |
It was the lighter. Somehow the insides of the lighter had gotten twisted enough that at one little point there was just enough contact with the outside of the body to cause the short. Loosened the nut that holds the assembly together, moved the inside works about 1//32". Problem solved! Thanks all! Bob Johnson BJ8 (cranked and running again) |