I just received a replacement sending unit & installed it in a new fuel tank 
to test the gage/sending unit combination. With an empty tank, the gage reads 
1/4 full. I tested my original sending unit in the same tank & it also reads 
1/4 full, in an empty tank.
 
FYI, the reason I am replacing the OE sending unit is because the ohm reading 
is very erratic as the float is moved. I tried to repair it, unsuccessfully.
 
The depth from the mounting flange on the new tank to the bottom is the same 
as my old tank. The old sending unit reads about 16 ohms empty & the new one 
reads 22. Both sending units read about 2 ohms when the arm is moved to its 
"Lowest" position & the gage reads empty, but the bottom of the tank prevents 
the 
arms from going to their lowest position. If I bent the arm such that the 
reading is 2 Ohms when the tank is empty it will not read full when it is full. 
I 
guess this might be preferable to an empty tank that reads 1/4 full. Is this 
a common problem or am I just lucky? What would you suggest?
Thanks,
Gary Hodson  