Correction,
The 920 amps) should read (20 amps)
D
Carole and Jonathan Quandt wrote:
> The overdrive failed to engage during a weekend trip and my newly
> installed ammeter showed a 25amp discharge when the OD switch was
> engaged.I figured my OD solenoid was burned out and limped home at a
> pathetic 65 mph. This morning I removed the tunnel and removed a rather
> smelly OD solenoid.I decided to go through the solenoid lever
> adjustment procedure as outlined in the manual as well as Nock's
> version and noticed something which may be a problem . When the
> adjusting lever is pushed forward and the 3/16 pin inserted for the
> preset the lever is just beginning to encounter spring tension. If the
> rest of the adjustment is continued at this point my sense is that with
> the solenoid piston in the fully actuated position will not engage the
> unit . Again the locating pin seems to only take up the slack and the
> lever has more to go.Is this a sign of something wrong or should I just
> set the lever past the alignment holes ? Thanx Jonathan 56 BN2
|