I learned NOT to mount the fan in front of the radiator. It caused  
Peyote to actually overheat--first time ever. I'd never use the ties  
again either--they might be too soft to rub through the radiator  
metal, but the grit that gathers around them is not. I got a leaky rad  
from a push-through mount. I just made a bracket to mount the fan in  
back of the radiator (spaced well away) and ran it as a puller. You  
only run it on the grid or when tuning anyway. Now I actually have  
made a removable fan that I just stick in for hot days on the grid or  
tuning.

On Jun 29, 2008, at 1:47 PM, jim hearn wrote:

> I am trying to mount an electric pusher fan in lieu of the belt  
> driven fan
> to gain the hp.  The radiator in my '74 TR6 ex-SCCA racer is the high
> density type so I am not able to mount with ties the usual way  
> through the
> radiator.  Does anyone have any ideas as to a good way to mount the
> aftermarket fan?  Thanks for any ideas.  Jim
>
> [demime 1.01d removed an attachment of type application/ms-tnef  
> which had a name of winmail.dat]
> _______________________________________________
> http://www.team.net/donate.html
>
> Fot mailing list
> Fot@autox.team.net
> http://autox.team.net/mailman/listinfo/fot
>
> You are subscribed as billb@bnj.com

Bill Babcock
Babcock & Jenkins
Billb@bnj.com
503.936.7660
www.bnj.com
_______________________________________________
http://www.team.net/donate.html

Fot mailing list
Fot@autox.team.net
http://autox.team.net/mailman/listinfo/fot


<Prev in Thread] Current Thread [Next in Thread>